Stam, B.C. (2017) Measurements with time-of-flight detector for the new HypHI experiment. Bachelor's Thesis, Physics.
|
Text
BachelorResearchBirtheStam.pdf - Published Version Download (8MB) | Preview |
|
Text
Toestemming.pdf - Other Restricted to Backend only Download (80kB) |
Abstract
To confirm the existence of a recently seen neutral bound state, the 3Λn bound state, a new setup has to be made. In this research the time resolution of the Plastic Bowl detector will be determined and if possible improved. There has been found that the time resolution of this detector is not accurate enough to be used as a time-of-flight detector in the new HypHI experiment, but there might be possibilities to use it as a start detector for a drift chamber. The best found time resolution for one detector has a value of 0.386 ± 0.039 ns, while for using this detector as a time-of-flight detector a time resolution of approximately 0.20 ns is required.